The software now supports importing UV spectral data channels from an Agilent OpenLab .dx raw data file.
The software will now order the Data Channel list for the Agilent OpenLab raw data files based on detector type, then file size for easier selection.
The software now supports importing UV spectra stored in a double precision format from an Agilent .uv raw data file.
The software now supports importing chromatographic CDF files with non-uniform sampling and a raw data retention time array.
The software now supports importing additional sample acquisition metadata from Agilent ChemStation raw data files (.ch, .md, .uv) as Image Attributes.
Compatibility:
The auto-generated image file name for imported JEOL RBC and RPC files has been updated to include the more meaningful name of the raw data folder.
A new Data Channel parameter is added to the File Format options of Project's Auto Processing and Process Runs operations. A raw data file can contain multiple data channels. For example, an Agilent MassHunter or OpenLab data file may contain multiple FID and spectral data channels. This parameter allows users to select which data channel to be imported and processed by specifying the data channel name.
Common options are now listed first in the File Format UI for Project's Auto Processing and Process Runs operations.
The software now has a new Hybrid blob detection algorithm. The new algorithm combines 1D and 2D peak detection with options for shoulder detection and controlling how 1D peaks are merged.
Compatibility: The new Hybrid algorithm type is the new default. The previous blob detection algorithm can be used by setting Detection Type to 2D via Configure > Settings > Blob Detection.
The various Blob Detection settings panes have been updated to use a consistent layout and labels. Also, user input validation has been made consistent between Configure > Settings and Interactive Blob Detection. For example, the user now can turn off smoothing by specifying 0 as smoothing factors in both places.
CLIC Tool now shows the description for both selected function and blob property in a larger pane to the bottom.
For a blob or an area, the Context MS mode now includes the corresponding spectrum for library search based on current settings.
The software now includes a new CLIC function: STRCONTAIN( searchString, string ) for testing if a string contains the search string.
When the Blob Mouse-Over settings contained a CLIC column item, an uncaught exception would occur after performing Deconvolve/Unmix or Local Blob Detection actions.
When performing the Auto Feature step in Investigator with a data file on a network drive, the step would take a very long time.
When importing a plugin, entering a non-plugin directory path into the file browser would show a warning message instead of simply navigating to the location.
When saving a Summary Report as an Excel file, some Image Attribute values caused extremely wide columns in the spreadsheet.
The default value for Minimum Area of the Blob Detection settings has been changed from 5 to 15.