Update Notes R2.2 Update b5
GC Image Release 2.2b5 includes improvements and bug fixes over previous R2.2 releases.
If GC Image R2.2b4 or older 2.2 version is installed, then R2.2b5 can be installed as update by
downloading and executing the
update
program.
If an older GC Image R2.2 is not installed (or for a separate installation), then
R2.2b4 can be installed from scratch by downloading and executing the
installation
program, and then installing the update package.
Bug Fixes
- TIC values changed after correct baseline only on TIC, shift phase, save and reopen a MS image
- TIC in the CDF file was not updated after baseline correction and save a MS image
- Failed to add a projection line for a MS range in 1D View when a blob is selected
- Edit Vial Table in GC Project and then cancel cleared the dirty status of a modified project
- Tabbing into Amount Table in GC Project caused infinite loop
Previous Updates
Update Notes R2.2 Update b4
Bug Fixes
- Spectral filters were not applied when importing MassHunter data files
- No ISTD calibration function was created for named area objects
- Unicode characters are not read properly from an amount table linked to an image
- Cannot access amounts in a project at a network drive
- Deleted images from a project caused wrong image names to be used when creating a Batch
- Changing active spectrum in MS Viewer did not update the TIC value displayed
- Some blobs were not drawn due to incorrect calculation
- Resizing TIC window caused proceeding SICs not to be in sync
- Hot keys for menu items did not work correctly
- 3D view's information mode was not updated when configuration changed
- Exception when aborting auto generate feature template with Image Investigator
- Match Template step in Image Investigator reported numbers of peaks and matched peaks as floating point numbers instead of integers
Update Notes R2.2 Update b3
Improvements
- Report one-way ANOVA F-test statistic (F Value) in addition to pairwise maximum Fisher Discriminant Ratio (FDR) for multi-class analysis in Image Investigator.
- Improved Amount Table editing interface in GC Project
- Support modulation XML files in Agilent ChemStation .D folder
- Improved command-line interfaces for invoking GC Image from instrument data systems
Bug Fixes
- Refresh Template Object Table did not work immediately after Load Template
- Arithmetic Operation calculated wrong values when spectra have an intensity offset
- Could not save Blob Set Table directly from GC Project
- Edit Record in Amount Table displayed but did not save new values
- Image Investigator failed to load images with areas and graphic column
- Exception when save image after detecting blobs with no filter
- Exception when uninclude selected graphics in Blob Set Table
- Exception when selecting a row in any Data Table then closing Image Investigator
- Process runs with Blob Set Table configuration changed the display of BST in all old images
- View Blob Set Table in GC Project did not use the saved configuration
- One library was missing from the list after set default to Library Search settings
- Wrong tooltip for MassRank() in CLIC Calculator
- Wrong labels for parametric moments in Blob Statistics settings
Update Notes R2.2 Update b2
Improvements
- Add support for using included graphics to determine response factors for unknowns
- Improved performance in Blob Table when many many blobs are detected
Bug Fixes
- Incorrect response factors in the distributed Compound Library (Note: the fix is not updatable. Fresh installation is required.)
- Got different response factors for the same compound after changing Compound Library
- Reported different responses for a blob in two included graphics by Corrected Fractional Response Report
- Area objects were counted toward total volume of blobs in Corrected Fractional Response Report
- Undo Local Blob Detection or Draw Blob did not undo NN blob and made saved images corrupted
- Volume changed on a blob locally detected on SIC after save
- Local Blob Detection set wrong NN on wrap-around blobs
- Local Blob Detection calculated wrong volume on overlapping blob
- Export Blob MS as Text MS file saved wrong header
- Exception when Export Text MS - Close - Export Text MS for Blobs
- Could not open image created by a project with "&" in the name
- Import Agilent CH files did not always detect EOF correctly
- Export Method did not list all report configurations
- Use Method when Import Image did not load the report configuration in the Method folder
- Export Method with current color map did not save the color map correctly
Update Notes R2.2 Update b1
Improvements
- Improved multi-channel baseline correction on all channels
- Smaller graph margins used in 1D View to display more graphs at the same time
- Better representation, sorting and saving in Statistics data table in Image Investigator
Bug Fixes
- Wrong tool tips in Export Profile Data to Centroid Data dialog (GCxGC-HRMS edition)
- Fail to report error when saving more than 255 columns to Microsoft Excel XLS files
- Generate Feature Template step fail to load preview when performing Auto Feature Template in Image Investigator
- Exception when sorting Area Table in Image Investigator
- The order of compounds in Image Investigator depends on the sorting order of Blob Table in GC Image
- Initial CLIC image is offset when Synchronizing View setting is on
- Wrong column names in Fractional Response Report
- Missing labels in control panels of 3D View and MS Cube
- Does not import GCR (filter rule) file with Import Action for Processing folder in GC Project
- Exception when deleting many many entries in Compound Library
- View Spectrum menu shows fewer locations in 1D View
- GC Image does not accept paths with foreign chars from command line
- Always add 1 to negative integer intensity when importing Text MS file
- Show m/z=0 when two intensities from two spectra canceled out when view Blob MS
- Moving projection lines leaves out a trace on Image Viewer when the image is big
Contact Information
For information about licensing GC Image software, contact:
Zoex Corporation
11665 Fuqua St, Suite B202
Houston TX 77034
Email: info@zoex.com
Phone: 1.281.484.2828
Fax: 1.281.484.0808
URL: http://www.zoex.com
For technical information about GC Image software, contact
GC Image, LLC
PO Box 57403
Lincoln NE 68505-7403 USA
Email: info@gcimage.com
Phone: 1.402.310.4503
URL: http://www.gcimage.com
GC Image™ © 2001–2011, by GC Image, LLC and the University of Nebraska.